TM 9-2330-385-14
Table 4-1. Unit Maintenance Preventive Maintenance Checks and Services - CONT.
Item
Interval
Item to Be
Procedure
Not Mission
No.
Inspected
Capable If:
NOTE
If an air-operated grease gun does not purge
D
the fitting, use a hand-operated grease gun.
If the part does not purge, remove fitting and
clean, install fitting and grease again. If part
still does not purge, refer to maintenance
task for that component.
When using a grease gun, apply lubricant to
D
the fitting until clean lubricant squeezes out
of the part being lubricated.
18
Annual
Drawbar
Lubricate the drawbar bushings with GAA
Fittings will not purge
bushings
every 6,000 miles (9,654 km) or annually,
old lubricant out of
whichever comes first.
component.
4-17
|