Click here to make tpub.com your Home Page

Page Title: Installation.
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2330-385-14
4-40. EMERGENCY BRAKE AIR LINE REPLACEMENT (CONT).
(9)
Remove adapter fitting (12) with
gladhand (13) from air line (1).
(10)
Remove adapter fitting (12) from
gladhand (13).
NOTE
Perform step (11) if seal or
screen is damaged.
(11)
Remove seal (14) and screen (15) from
gladhand (13).
b.
Installation.
NOTE
Perform step (1) if seal or screen
was removed.
14
(1)
Install screen (15) and seal (14) on
gladhand (13).
13
15
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
Use sealing compound sparingly
and only on threads. Do not
apply compound on hose
connections. Damage to
equipment may result.
(2)
Apply sealing compound on threads of
fitting (12).
(3)
Install adapter fitting (12) on emergency air
line (1).
(4)
Install gladhand (13) on adapter fitting (12).
4-442

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business