![]() TM 9-2330-385-14
4-41. AIR RESERVOIR NO. 1 REPLACEMENT (CONT).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
Use sealing compound sparingly and only on threads. Do not apply compound on hose
connections. Damage to equipment may result.
(10)
Apply sealing compound on threads of
reducer (19).
(11)
Install reducer (19) on air reservoir (13).
(12)
Apply sealing compound on threads of
elbow (18).
(13)
Install elbow (18) on reducer (19).
(14)
Apply sealing compound on threads of
T-fitting (15).
(15)
Install T-fitting (15) on air reservoir (13).
(16)
Apply sealing compound on threads of
reducer (17).
(17)
Install reducer (17) on T-fitting (15).
Do not tighten check valve by its body. Damage to check valve may result.
NOTE
The valve is marked with an arrow indicating the direction in which it should be installed.
Note direction of arrow before installation.
(18)
Apply sealing compound on threads of check valve (16).
(19)
Install check valve (16) on reducer (17).
(20)
Apply sealing compound on threads of elbow (10).
(21)
Install elbow (10) on check valve (16).
(22)
Apply sealing compound on threads of elbow (9).
(23)
Install elbow (9) on T-fitting (15).
4-448
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |