b.
Installation.
(1)
Install bulkhead adapter (4) on bracket (11), with lockwasher (10) and nut (9).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors and are
harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
Use sealing compound sparingly
and only on threads. Do not
apply compound on hose
connections. Damage to
equipment may result.
(2)
Apply sealing compound on threads on both
ends of fitting (8).
(3)
Install fitting (8) on bulkhead adapter (4).
(4)
Apply sealing compound on threads of
filter (7).
(5)
Install filter (7) on fitting (8).
(6)
Apply sealing compound on threads of
fitting (6).
(7)
Install fitting (6) on filter (7).
(8)
Install air line 2229 (5) on fitting (6).
(9)
Apply sealing compound on threads of both
ends of fitting (3).
(10)
Install fitting (3) on bulkhead adapter (4).
(11)
Install protective cover (1) and quick
disconnect (2) on adapter fitting (3).
(12)
Install protective cover on quick
disconnect (2).
c.
Follow-On Maintenance:
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).