Click here to make tpub.com your Home Page

Page Title: Follow-On Maintenance:
Back | Up | Next

Click here for thousands of PDF manuals

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Logistics
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
   
   

 

TM 9-2330-385-14
NOTE
Ensure that the screw holes are
at the top of the valve during
installation.
(14)
Install valve (5) on bracket (8) with two
screws (7) and locknuts (6).
(15)
Install washer (4) and nut (3) on shaft (2).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
(16)
Apply sealing compound to threads of
shaft (2).
(17)
Turning to the right, install knob (1) on
shaft (2).
c.
Follow-On Maintenance:
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).
END OF TASK
4-467

Privacy Statement - Press Release - Copyright Information. - Contact Us

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business