![]() TM 9-2330-385-14
(6)
While holding adjustment screw (4), loosen
jam nut (5) on safety valve (6).
(7)
Apply sealing compound to threads of valve
(6) and install on elbow (7).
NOTE
If safety valve can not be
adjusted to release at 53-56 psi
(365-386 kPa) or 95-100 psi
(655-689 kPa) if equipped with
drawbar extension, replace valve.
(8)
Repeat Steps (3) through (7) until safety
valve releases at 53-56 psi (365-386 kPa) or
95-100 psi (655-689 kPa) if equipped with
drawbar extension.
(9)
Drain trailer air system, (Para 2-21).
(10)
Disconnect 0-160 psi (0-1103 kPa) pressure
gage from air hose 2224 (1) and adapter
(2).
(11)
Install air hose 2224 (1) to adapter (2).
Follow-On Maintenance:
d.
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).
END OF TASK