![]() TM 9-2330-385-14
(3)
Remove two elbows (4) and (5) and fitting (6) from quick release valve (9).
b.
Installation.
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
Use sealing compound sparingly and only on threads. Do not apply compound on hose
connections. Damage to equipment may result.
(1)
Apply sealing compound on threads of
fitting (6).
(2)
Install fitting (6) on quick release valve (9).
(3)
Apply sealing compound on threads of
elbow (5).
(4)
Install elbow (5) on quick release valve (9).
(5)
Apply sealing compound on threads of
elbow (4).
(6)
Install elbow (4) on quick release valve (9).
(7)
Install quick release valve (9) on
bracket (10) with two screws (8) and
locknuts (7).
(8)
Install air lines 2260 (1), 2660 (2) and
2639 (3) on elbows (4) and (5) and
fitting (6).
c.
Follow-On Maintenance:
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).
END OF TASK