TM 9-2330-385-14
4-52. MULTIFUNCTION VALVE REPLACEMENT (CONT).
b.
Installation.
NOTE
If replacing valve with new
valve, perform Steps (1)
through (6).
Only remove two screws at
a time.
Screws must be removed
diagonally from each other.
(1)
Remove two screws (28) from new
valve (20). Discard screws.
(2)
Remove two nuts (29), lockwashers (30)
and studs (26) from old valve (20). Discard
(3)
Insert two 1/4 in. (6.4 mm) by 3/4 in.
(19 mm) screws (28) in old valve.
Adhesives, solvents and sealing
compounds can burn easily, can
give off harmful vapors and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and
water.
(4)
Apply sealing compound to stud holes.
(5)
Install two studs (26), nut (29) and
lockwasher (30) in new valve (20).
(6)
Repeat Steps (1) through (5) for remaining
two studs (26).
4-494
|