4-67. FLATRACK AIR CHAMBER REPLACEMENT (CONT).
Use care when installing springs.
Springs are under tension and
can act as projectiles when
released. Injury to personnel
may result.
(9)
Install washer (10), coil spring (11) and
washer (12) on locking pin (8) with cotter
pin (9).
(10)
Turn unlocking rod to the left and remove
from threaded hole (3) of flatrack load
lock (5) to extend load lock.
(11)
Install cap (1) on cable (2) in threaded hole
(3).
c.
Follow-On Maintenance:
Uncage flatrack air chamber, (Para 4-65).
Charge air system, (Para 2-22).
Check for air leaks, (Para 4-7).
Remove wheel chocks, (Para 2-20).
END OF TASK