TM 9-2330-385-14
5-24. EXTENDED DRAWBAR/LIGHT BAR KIT INSTALLATION (CONT).
16
12
24
22
23
15
32
31
21
18
17
(25)
Install adjusting pin (16) in tube assembly (12) with tube assembly in extended mode.
Adhesives, solvents and sealing compounds can burn easily, can give off harmful vapors and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
(26)
Apply adhesive sealant on end of tube assembly (12).
(26.1)
Apply sealing compound to threads of six screws (17).
(27)
Position safety arm (31) in retaining guide (21) and install plate (32) on tube assembly (12) with six
screws (17) and lockwashers (18).
(28)
Remove adjusting pin (16) and position tube assembly (12) in retracted position.
(29)
Install adjusting pin (16) and raise hinge assembly locking latch (15) into locked position.
(30)
Tighten four locknuts (24) on screws (23) and clamps (22).
5-90
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |