![]() TM 9-2330-385-14
5-24. EXTENDED DRAWBAR/LIGHT BAR KIT INSTALLATION (CONT).
38
40
40
39
NOTE
Both gladhands and air hoses are
38
removed the same way.
37
(34) Remove two gladhands (36) and adapter
fittings (37) from emergency brake air line
36
(38) and service brake air line (39).
(35) Remove emergency brake air line (38) and
service brake air line (39) from adapter
fittings (40).
Adhesives, solvents and sealing
compounds can burn easily,
can give off harmful vapors and
are harmful to skin and
clothing. To avoid injury or
death, keep away from open
fire and use in well-ventilated
area. If adhesive, solvent, or
39
sealing compound gets on skin
or clothing, wash immediately
37
with soap and water.
36
(36) Apply sealing compound on threads of two
adapter fittings (37) and (40).
NOTE
Air lines in Steps (37) and (38) are
from extended drawbar/light bar kit.
(37) Install emergency brake air line (38) and
service brake air line (39) on two adapter
fittings (40).
(38) Install two gladhands (36) and adapters (37)
on emergency brake air line (38) and service
brake air line (39).
5-92
|
Privacy Statement - Press Release - Copyright Information. - Contact Us |