TM 9-3990-206-14&P
9-28. REAR WALL FLOOR BOARD REPLACEMENT (CONT).
b.
Installation.
Ensure all personnel wear protective gloves when handling rear wall floor board to protect
hands from wood splinters. Failure to comply may result in injury to personnel.
Wood waterproofing is hazardous and flammable. Do not breath vapors and only apply
waterproofing in a well-ventilated area. Keep away from open flames. Wear protective
gloves and eye protection when applying waterproofing. Failure to comply may result in
injury or death to personnel.
(1)
Apply waterproofing to all wood surfaces
that have been cut and all exposed surfaces
that do not have waterproofing applied.
(2)
Position rear wall floor board (2) on rear
wall (3).
(3)
Scribe a line on rear wall floor board (2) to
correspond with center of each
crossmember (4).
(4)
Drill 7/32 in. (5.56 mm) pilot holes in rear
wall floor board (2) and crossmember (4).
(5)
Install screws (1) in rear wall floor board (2)
and crossmember (4). Tighten screws until
head of screw is below surface of rear wall
floor board.
c.
Follow-On Maintenance:
Lower rear wall, (Para 7-10).