4-8. PMCS TABLE (CONT).
Table 4-1. Unit Maintenance Preventive Maintenance Checks and Services - CONT.
Interval
Item to Be
Procedure
Not Mission
Item
Inspected
Capable If:
No.
3.88 IN.
MAXIMUM
(9.86 CM)
1
14
Semi-
Flatrack
Check inside diameter of both flatrack locks for
Flatrack lock inside
Annual
locks
wear. If inside diameter is greater than 3.88 in
diameter is greater than
(9.86 cm), replace flatrack lock (Para 4-66).
3.88 in. (9.86 cm).
15
Semi-
Suspension
Check all suspension mounting hardware (1)
Suspension hardware is
Annual
for looseness and damage. Check for move-
missing, loose or
ment of springs (2) by looking for signs of rust
damaged.
or shiny spots on spring and mounting
hardware that indicate spring movement. If
springs are loose or hardware is damaged,
notify Direct Support Maintenance.