DRAFT
TB 9-2320-364-13&P-1
AC HEATER/EVAPORATOR BLOWER OPERATES BUT NO COLD AIR FROM AC
DUCTS DURING AC OPERATIONS - Continued
Table 3-2.
Operator's Troubleshooting (Continued)
WP
MALFUNCTION
SEQUENCE
TEST OR INSPECTION
NO.
CORRECTIVE ACTION
Step 7. Open side access cover (TM 9-2320-364-10).
PLS155
Step 8. Inspect AC compressor belts for looseness and damage.
If AC compressor belts are loose, damaged, or missing, notify Field
Level Maintenance.
Step 9. Close side access cover (TM 9-2320-364-10).
Step 10. Start engine and operate AC system (WP 0004).
If AC system fails to provide cold air, or stops providing cold air during
normal operations, notify Field Level Maintenance.
END OF WORK PACKAGE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
0007-3/(0007-4 blank)