OPERATOR'S TROUBLESHOOTING INTRODUCTION
Table 3-2. Operator's Troubleshooting

Air Conditioning System Nsn 4120-01-526-9158 P/N 3528349 For Truck, Tractor M1074/M1075 Palletized Load System Page Navigation
  15    16    17    18    19  20  21    22    23    24    25  
img
. . .
DRAFT
TB 9-2320-364-13&P-1
0006
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
Table 3-1.
Operator's Troubleshooting
WP
MALFUNCTION
SEQUENCE
TEST OR INSPECTION
NO.
CORRECTIVE ACTION
0006
AC HEATER/EVAPORATOR BLOWER DOES NOT OPERATE.
PLSAC152
Step 1. Check if engine start switch is positioned to ON (TM 9-2320-364-10).
Position engine start switch to ON.
Step 2. Check if AC circuit breaker is tripped.
If AC circuit breaker is tripped, reset circuit breaker. If circuit breaker
trips after resetting, notify Field Level Maintenance.
Step 3. Check if fan control switch is set to the correct operating position (WP 0004).
Place fan control switch in the correct operating position.
If fan control switch is in the correct operating position and AC
heater/evaporator blower does not operate, notify Field Level
Maintenance.
END OF WORK PACKAGE
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -