DRAFT
TB 9-2320-364-13&P-1
AC COMPRESSOR DOES NOT SHUT OFF OR CYCLES CONSTANTLY - Continued
WARNING
Remove rings, bracelets, wristwatches, neck chains, and any other jewelry before working around
vehicle. Jewelry can catch on equipment and cause serious injury. Jewelry or tools may short
across electrical circuits or terminals and cause damage to equipment or severe burns or
electrical shock to personnel.
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -
CONTINUITY TEST
NOTE: Do not disconnect wires from AC condenser
motor.
(3) Place positive (+) probe of multimeter on red wire at
AC condenser motor terminal.
(4) Place negative (-) probe of multimeter on red wire at
go to Step 15 of this fault.
(b) If there is continuity, go to Step 12 of this fault.
CONTINUITY TEST
(2) Place positive (+) probe of multimeter on ground
wire at AC condenser motor terminal.
(3) Place negative (-) probe of multimeter on ground
wire at other end.
repair, go to Step 15 of this fault.
(b) If there is continuity, replace AC condenser
this fault.
PLSAC177