TM 9-2320-364-20-2
2-1190
6. WORK LIGHT(S) WILL NOT OPERATE (CONT).
2.
Replace work light
lamp (Para 7-55).
Verify repair, go to
Step 14 of this Fault.
YES
NO
Headlights operate, indicating
12 vdc input to circuit breaker
CB4.
Work light lamp faulty.
Work light internal power wire
faulty.
Work light internal switch faulty.
Work light internal ground wire
faulty.
Wire 1435 at work light harness
connector faulty.
Circuit breaker CB4 faulty.
Wire 1040 faulty.
Wire 1040A faulty.
Wire 1435 between relay R4
and ground faulty.
Relay R4 faulty.
Wire 1292 faulty.
Work light switch faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If lamp filament faulty, lamp will
not light.
WARNING
3.
Repair internal
power wire 1040B
(see schematic
Fig 2-27) or notify
DS Maintenance.
Verify repair, go to
Step 14 of this Fault.
YES
NO
Headlights operate, indicating
12 vdc input to circuit breaker
CB4.
Work light lamp OK.
Work light internal power wire
faulty.
Work light internal switch faulty.
Work light internal ground wire
faulty.
Wire 1435 at work light harness
connector faulty.
Circuit breaker CB4 faulty.
Wire 1040 faulty.
Wire 1040A faulty.
Wire 1435 between relay R4
and faulty.
Relay R4 faulty.
Wire 1292 faulty.
Work light switch faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
If continuity is not measured,
work light internal power wire is
faulty and work light will not
operate.
WARNING
Is continuity measured across
work light lamp?
Is continuity measured from
terminal A of faulty work light
connector to internal power
wire 1040B at wire nut?
Read WARNING
on Page 2-1191
Read WARNING