TM 9-2320-364-20-2 2-1218 9.  BEACON LIGHT DOES NOT OPERATE (CONT). Horn operates, indicating circuit   breaker CB3 OK. Dome light operates, indicating   10 to 14 vdc to wire 1276. 10 to 14 vdc are supplied to   wire 1029. Wire 1435 faulty. Wire 1276 faulty. Beacon light switch faulty. Wire 1413 faulty. Wire 1184 faulty. Relay R6 not grounded. Beacon relay R6 faulty. Wire 1029 faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If beacon light is not grounded, beacon light will not operate. YES NO Repair wire 1435 (see schematic Fig 2-30) or notify DS Maintenance. Verify repair, go to Step 9 of this Fault. 2. Is continuity measured on wire 1435 between connector and a known good ground? Replace beacon light (TM 9-2320-364-10). Verify repair, go to Step 9 of this Fault. WARNING Read   WARNING on Page 2-1219