TM 9-2320-364-20-2
2-1222
9. BEACON LIGHT DOES NOT OPERATE (CONT).
5.
Repair wire 1413
(see schematic
Fig 2-30) or notify
DS Maintenance.
Verify repair, go to
Step 9 of this Fault.
YES
NO
Horn operates, indicating circuit
breaker CB3 OK.
Dome light operates, indicating
10 to 14 vdc to wire 1276.
Wire 1435 OK.
Wire 1276 OK.
Beacon light switch OK.
Wire 1413 faulty.
Wire 1184 faulty.
Relay R6 not grounded.
Beacon relay R6 faulty.
Wire 1029 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If wire 1413 is loose, faulty, or
shorted to ground, beacon light
will not operate.
6.
Repair wire 1184
(see schematic
Fig 2-30).
Verify repair, go to
Step 9 of this Fault.
YES
NO
Horn operates, indicating circuit
breaker CB3 OK.
Dome light operates, indicating
10 to 14 vdc to wire 1276.
Wire 1435 OK.
Wire 1276 OK.
Beacon light switch OK.
Wire 1413 OK.
Wire 1184 faulty.
Relay R6 not grounded.
Beacon relay R6 faulty.
Wire 1029 faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Voltage test.
STE/ICE-R #89.
If wire 1184 is loose, faulty, or
shorted to ground, beacon light
will not operate.
WARNING
Are 10 to 14 vdc measured on
wire 1413 at beacon relay R6,
terminal 30?
Are 10 to 14 vdc measured on
wire 1184 at beacon relay R6,
terminal 85?
Read WARNING
on Page 2-1223
|