TM 9-2320-364-20-2
2-1275
(1) Set multimeter select switch to
volts dc.
(2) Connect positive (+) multimeter lead
to socket power contact of turn signal
socket.
(3) Connect negative () multimeter lead
to a known good ground.
(4) Turn on right turn signal.
(a) If 2 to 10 vdc are not present,
turn off right turn signal and go to
Step 4 of this Fault.
(b) If 2 to 10 vdc are present, turn off
right turn signal and go to Step 3
of this Fault.
VOLTAGE TEST
Remove all jewelry such as rings, dog tags, bracelets, etc. If jewelry or tools contact positive electrical
circuits, a direct short may result. Damage to equipment, injury or death to personnel may occur.
(1) Set multimeter select switch to ohms.
(2) Is there continuity between socket
ground contact and a known
good ground?
(a) If there is no continuity, replace
composite light.
(b) If there is continuity and fault not
corrected, perform Steps (3) and
(4) below and notify DS
Maintenance.
(3) Install turn signal lamp.
(4) Install preformed packing and
composite light cover and tighten
six screws.
CONTINUITY TEST
Voltage will pulsate between 2 and 10 vdc
during turn signal voltage tests.
NOTE
|