TM 9-2320-364-20-3
2-2929
(1) Set multimeter select switch to ohms.
(2) Is there continuity on wire 1435
between connector, terminal 1
and a known good ground?
(a) If there is no continuity, perform
Steps (3) and (4) below and repair
wire 1435 (see schematic
Fig 2-67), or notify DS
Maintenance.
(b) If there is continuity, fault not
corrected, notify DS Maintenance.
(3) Connect connector to high speed
solenoid valve M51.
(4) Tighten screw and coat head of
screw with adhesive.
CONTINUITY TEST
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin
and clothing. To avoid injury or death, keep away from open fire and use in a well-ventilated area. If adhesive,
solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water.
MULTIFUNTION
MANIFOLD
CONNECTOR
HIGH SPEED
FAN SOLENOID
VALVE
M51
TERMINAL 1
|