TM 9-2320-364-20-3 2-2390 10.  HOOK ARM DOES NOT LOAD IN MANUAL MODE (CONT). 5. Repair wire 1486 (see schematic Fig 2-52) or notify DS Maintenance. Verify repair, go to Step 10 of this Fault. YES NO LHS hoses OK. LHS tubes OK. Wire 1490 OK. Wire 1486 faulty. Hydraulic selector switch faulty. LHS control assembly faulty. Wire 1467 faulty. Wire 1435 faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If wire 1486 is loose, faulty, or shorted to ground, 22 to 28 vdc will not be present at LHS control assembly from hydraulic selector switch. WARNING Is continuity measured on wire 1486 at harness connector MC83, terminal C and harness connector MC94, terminal B? Read   WARNING on Page 2-2391