Order this information in Print

Order this information on CD-ROM

Download in PDF Format

     

Click here to make tpub.com your Home Page

Page Title: 10. HOOK ARM DOES NOT LOAD IN MANUAL MODE (CONT)
Back | Up | Next

Click here for a printable version

Google


Web
www.tpub.com

Home


   
Information Categories
.... Administration
Advancement
Aerographer
Automotive
Aviation
Combat
Construction
Diving
Draftsman
Engineering
Electronics
Food and Cooking
Math
Medical
Music
Nuclear Fundamentals
Photography
Religion
USMC
   
Products
  Educational CD-ROM's
Printed Manuals
Downloadable Books
   

 

TM 9-2320-364-20-3 2-2392 Is continuity measured at hydraulic selector switch harness connector MC94, terminal B and terminal F with switch in MAN HA position? 10.  HOOK ARM DOES NOT LOAD IN MANUAL MODE (CONT). 6. Replace hydraulic selector switch (Para 7-31). Verify repair, go to Step 10 of this Fault. YES NO LHS hoses OK. LHS tubes OK. Wire 1490 OK. Wire 1486 OK. Hydraulic selector switch faulty. LHS control assembly faulty. Wire 1467 faulty. Wire 1435 faulty. KNOWN INFO POSSIBLE PROBLEMS TEST OPTIONS REASON FOR QUESTION Continuity test. STE/ICE-R #91. If hydraulic selector switch is faulty, 22 to 28 vdc will not be present at LHS control assembly. WARNING Read   WARNING on Page 2-2393

Privacy Statement - Press Release - Copyright Information. - Contact Us - Support Integrated Publishing

Integrated Publishing, Inc. - A (SDVOSB) Service Disabled Veteran Owned Small Business