TM 9-2320-364-20-3
2-2502
15.
Repair wire 1435 (see
schematic Fig 2-56) or
notify DS Mainte-
nance. Verify repair,
go to Step 18 of this
Fault.
YES
NO
No mission module hooked up
to interface quick disconnect.
LED #2 lamp OK.
Wire 1790 between LED #2
lamp and relay R35 terminal
87 OK.
Relay R35 OK.
Wire 1734 between relay R35
terminal 30 and resistor OK.
Resistor OK.
Wire 1734 between resistor and
rectifier terminal AC OK.
Wire 1734 between resistor and
connector MC135 terminal B
OK.
Wire 1734 between connector
MC135 terminal B and
connector MC132 terminal 1
OK.
Wire 1435 between connector
MC132 terminal 2 and
connector MC135 terminal C
OK.
Wire 1435 between connector
MC135 terminal C and LED #2
lamp faulty.
Wire 1435 between LED #2
lamp and relay R35 terminal 85
faulty.
Wire 1734 between relay R35
terminal 86 and resistor faulty.
KNOWN INFO
POSSIBLE PROBLEMS
TEST OPTIONS
REASON FOR QUESTION
Continuity test.
STE/ICE-R #91.
LHS will not operate if wire
1435 is not grounded.
Is continuity measured on
wire 1435 between connector
MC135 terminal C and power-
box terminal 14?
15 LHS INOPERATIVE WITH INTERFACE KIT INSTALLED (CONT).
WARNING
Read WARNING
on Page 2-2503
|