TM 9-2320-364-20-4
3-26
3-9. REMOTE ENGINE OIL FILTER MANIFOLD REPAIR (CONT).
b.
Disassembly.
(1)
Position remote engine oil filter manifold
(1) in soft jawed vice.
NOTE
Note location and position of
adapter prior to removal.
(2)
Remove adapter (2) from remote engine oil
filter manifold (1).
Use care when installing springs.
Springs are under tension and
can act as projectiles when
released and could cause injury
to personnel.
(3)
Remove plug (3), washer (4), spring (5) and
valve disk (6) from remote engine oil filter
manifold (1).
(4)
Remove remote engine oil filter manifold
(1) from vise.
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when
using solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees
C) and Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may
result in injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal parts with drycleaning solvent.
1
2
3
4
6
5
|