TM 9-2320-364-20-4
4-90
4-19. ETHER STARTING AID HOSE AND FITTINGS REPLACEMENT (CONT).
(4)
Open engine cover.
(5)
Remove nut (6), ferrule (7) and ether tube (1) from atomizer (8). Discard nut, ferrule and ether tube.
b.
Installation.
Starting fluid is toxic and highly flammable. Container is pressurized. NEVER heat container
and NEVER discharge starting fluid in confined areas or near open flame. Severe injury to
personnel may result.
(1)
Install nut (6) and ferrule (7) on ether tube (1).
(2)
Install ether tube (1) on atomizer (8).
(3)
Close engine cover.
|