TM 9-2320-364-20-4
7-35
b.
Installation.
NOTE
Install cable ties as needed.
(1)
Install mounting bracket (80), two washers
(79), lockwashers (78) and screws (77) on
electric bracket (5).
(2)
Install standoff bracket (30), two washers (76),
lockwashers (75) and screws (74) on electric
bracket (5).
(3)
Install solenoid switch bracket (69), capacitor
(73), two washers (72), lockwashers (71) and
screws (70) on electric bracket (5).
(4)
Install solenoid switch (44), two screws (67),
and locknuts (68) on solenoid switch bracket
(69).
(5)
Install voltage regulator (38), two
washers (66), lockwashers (65) and
screws (64) on electric bracket (5).
Ensure an insulator plate and two
nylon shoulder washers are
installed in Step (6). If these items
were not present during removal,
they must be ordered and installed.
Failure to comply may result in
damage to equipment.
(6)
Install insulator plate (63), DUVAC controller
(10), two nylon shoulder washers (62),
washers (61), lockwashers (60) and
screws (59) on electric bracket (5).
|