TM 9-2320-364-20-4
7-45
(9)
Remove nut (40), lockwasher (41) and wire
1055 (42) from stud (43) of 24 volt solenoid
switch (44). Discard lockwasher.
(10)
Remove nut (40), lockwasher (41), wire
1045 (45) and capacitor wire (46) from
stud (47) of 24 volt solenoid switch (44).
Discard lockwashers.
(11)
Remove nut (48), lockwasher (49) and wire
1021A (50) from stud (51) of 24 volt
solenoid switch (44). Discard lockwasher.
(12)
Remove nut (48), lockwasher (49) and two
wires 1435 (52) from stud (53) of 24 volt
solenoid switch (44). Discard lockwasher.
(13)
Remove jumper diode wire (54) from stud
(51) and stud (53).
(14)
Remove capacitor (55) from stud (47) and
stud (53).
(15)
Remove four screws (56), lockwashers (57)
and electric bracket (5) from air cleaner
bracket (58). Discard lockwashers.
|