TM 9-2320-364-20-4
7-46
7-11. POLARITY PROTECTION CONTROL REPLACEMENT (200 AMP) (CONT).
(16)
Position electric bracket (5) on clean work
bench.
(17)
Remove two screws (59), lockwashers
(60), washers (61), and polarity protection
controller (10) from electric bracket (5).
Discard lockwashers.
(18)
Remove two screws (62), locknuts (63) and
24 volt solenoid switch (44) from solenoid
switch bracket (64). Discard locknuts.
(19)
Remove two screws (65), lockwashers
(66), washers (67), capacitor (68) and
solenoid switch bracket (6) from electric
bracket (5). Discard lockwashers.
(20)
Remove two screws (69), lockwashers
(70), washers (71) and standoff bracket
(31) from electric bracket (5). Discard
lockwashers.
(21)
Remove two screws (72), lockwashers
(73), washers (74) and mounting bracket
(75) from electric bracket (5). Discard
lockwashers.
b.
Installation.
NOTE
Install cable ties as required.
(1)
Install mounting bracket (75), two washers
(74), lockwashers (73) and screws (72) on
electric bracket (5).
(2)
Install standoff bracket (31), two washers
(71), lockwashers (70) and screws (69) on
electric bracket (5).
|