TM 9-2320-364-20-4
7-148
7-43. OUTRIGGER PROXIMITY SWITCH REPLACEMENT (CONT).
(13)
Remove screw (27) and brown wire (28) from bus bar (16) at terminal 4 (29).
(14)
Remove screw (27) and black wire (30) from bus bar (16) at terminal 5 (31).
(15)
Disconnect blue wire (32) from bottom of ground strip (21) at terminal 2 (33).
(16)
Remove cover (34), washer (35), grommet (36) and cable (37) from junction box (13).
(17)
Remove grommet (9) from cable (37).
b.
Installation.
NOTE
Perform Steps (1) through (5) for left hand proximity switch.
Perform Steps (6) through (10) for right hand proximity switch.
(1)
Position grommet (9), cover (34), washer (35) and grommet (36), on cable (37) and install cable in
junction box (13).
(2)
Connect blue wire (32) on bottom of ground strip (21) at terminal 2 (33).
NOTE
Use cable ties as necessary to bundle wires.
(3)
Install brown wire (28) on bus bar (16) at terminal 4 (29) with screw (27).
(4)
Install black wire (30) on bus bar (16) at terminal 5 (31) with screw (27).
(5)
Tighten cover (34) on cable (37).
|