TM 9-2320-364-20-4
7-200
7-55. HAND HELD WORK LAMP ASSEMBLY REPAIR (CONT).
(13)
Remove locknut (19), screw (20) and hand
held work lamp assembly bracket (21) from
hand held work lamp assembly (2). Discard
locknut.
(14)
Remove locknut (22), screw (23) and magnet
mount (24) from hand held work lamp
assembly bracket (21). Discard locknut.
c.
Assembly.
(1)
Install magnet mount (24), screw (23) and
locknut (22) on hand held work lamp
assembly bracket (21).
NOTE
When properly installed, hand
held work lamp assembly should
rotate after bracket is tightened.
(2)
Install hand held work lamp assembly
bracket (21), screw (20) and locknut (19) on
hand held work lamp assembly (2).
(3)
Install connector adapter (14) and wire pin
guide (18) on wire harness (13).
NOTE
Ensure slots in wire pin guides
align with tab in electrical
connector adapter.
(4)
Install two wire pins (17) and wire pin
guide (18) in connector housing (15).
Use care when installing
retaining rings. Retaining rings
are under spring tension and can
act as projectiles when released
and could cause severe eye
injury.
(5)
Install retaining ring (16) in connector
housing (15).
(6)
Install connector adapter (14) on connector
housing (15).
|