TM 9-2320-364-20-4
7-237
Do not overtighten water
temperature gage sensor.
(4)
Install water temperature gage sensor (11) in
left thermostat housing (12). Tighten to
20 lb-in (2.25 N.m).
(5)
Install washer (10), washer (9), wire
1320 (8), lockwasher (7) and nut (6) on
water temperature gage sensor (11).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap water.
(6)
Apply electrical sealant to terminal on water
temperature gage sensor (11).
(7)
Install 22 washers (3), lockwashers (2),
screws (1) and cab engine access panel (4) in
cab (5).
c.
Follow-On Maintenance:
Install fire extinguisher, (TM 9-2320-364-10).
Fill cooling system, (Para 6-4).
Start engine, (TM 9-2320-364-10).
Allow engine to run for three minutes.
Shut OFF engine, (TM 9-2320-364-10).
Check for coolant leaks, (TM 9-2320-364-10).
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
|