TM 9-2320-364-20-4
7-275
NOTE
Install cable ties as required.
(1)
Shift transfer case into High range (HI).
(2)
Install ball (6), detent spring (5) and rod (4)
in transfer case housing (7).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and
water.
NOTE
Remove and discard aluminum gasket from new neutral start switch. Gasket is not needed for
installation.
(3)
Apply sealing compound to threads of fitting (3).
(4)
Install fitting (3) in transfer case housing (7). Tighten two to three turns past hand tight.
(5)
Apply sealing compound to threads of neutral start switch (2).
(6)
Install neutral start switch (2) in fitting (3).
|