TM 9-2320-364-20-4
7-276
7-83. TRANSFER CASE NEUTRAL START SWITCH REPLACEMENT (CONT).
(7)
Connect a multimeter on MC57
connector (1). Multimeter should indicate
no continuity:
(a)
If no continuity is measured, proceed
with Step (8).
(b)
If continuity is measured, turn out
neutral start switch (2) 3/4 of a turn
beyond the point where the
multimeter measures continuity.
(8)
With the aid of an assistant, shift transfer
case out of High range (HI). Multimeter
should measure continuity:
(a)
If continuity is measured, proceed
with Step (9).
(b)
If no continuity is measured, tighten
switch (2) and adapter (3) 3/4 of a
turn past the point where multimeter
measures continuity.
(9)
Shift transfer case into High range (HI).
Multimeter should measure no continuity.
(10)
Remove multimeter from MC57
connector (1).
(11)
Connect MC57 connector (1).
c.
Follow-On Maintenance:
Position LHS in transit position, (TM 9-2320-364-10).
Check operation, (TM 9-2320-364-10).
Remove wheels chocks, (TM 9-2320-364-10).
END OF TASK
|