TM 9-2320-364-20-4
7-293
c.
Cleaning/Inspection.
Drycleaning Solvent (P-D-680) is TOXIC and flammable. Wear protective goggles, face
shield, and gloves; use only in a well-ventilated area; avoid contact with skin, eyes, and
clothes, and do not breathe vapors. Keep away from heat or flame. Never smoke when using
solvent. The flashpoint for Type II Drycleaning Solvent is 140 degrees F (60 degrees C) and
Type III Drycleaning Solvent is 200 degrees F (93 degrees C). Failure to do so may result in
injury or death to personnel.
If personnel become dizzy while using cleaning solvent, immediately get fresh air and
medical help. If solvent contacts skin or clothes, flush with cold water. If solvent contacts
eyes, immediately flush eyes with water and get immediate medical attention.
(1)
Clean all metal hook components with drycleaning solvent.
(2)
Inspect hook for cracks or deterioration.
(3)
Clean battery box with clean cloths and detergent.
(4)
Inspect for cracks or breaks.
(5)
Replace all damaged parts.
d.
Assembly.
(1)
Install hook anchor brackets (18), screws (20) and two locknuts (19) on battery box cover (21).
NOTE
Do not overtighten locknuts. Latch should move freely when properly assembled.
(2)
Install two rubber hooks (17), screws (16) and locknuts (15) on hook anchor brackets (18).
|