TM 9-2320-364-20-4
7-342
7-99. SLAVE CONNECTOR AND CABLE REPLACEMENT (CONT).
(2)
Remove screw (4), lockwasher (5) and
positive cable (Pos) 1138 (6) from receptacle
(7). Discard lockwasher.
(3)
Remove screw (8), lockwasher (9) and
negative cable (Neg) 1139 (10) from
receptacle (7). Discard lockwasher.
(4)
Remove locknut (11), screw (12) and
eyelet (13) from receptacle (7). Discard
locknut.
Note position of receptacle prior
to removal. Receptacle has
positive and negative side.
Failure to comply may result in
receptacle installed in incorrect
position and damage to
equipment may occur.
(5)
Remove three locknuts (14), screws (15),
insulator (16), gasket (17) and receptacle (7)
from air cleaner bracket (4). Discard
locknuts and gasket.
(6)
Remove locknut (18), screw (19) and
cushion clip (20) from air cleaner
bracket (4). Discard locknut.
(7)
Remove cushion clip (20) from positive
cable (Pos) 1138 (6) and negative cable
(Neg) (10).
|