TM 9-2320-364-20-4
7-343
(8)
Remove nut (21), lockwasher (22) and wire
1138 (6) from starter (23). Discard
lockwasher.
(9)
Remove nut (24), lockwasher (25) and wire
1139 (10) from starter solenoid (26).
Discard lockwasher.
b.
Installation.
(1)
Install wire 1139 (10), lockwasher (25) and
nut (24) on starter solenoid (26). Tighten
nut to 30 lb-ft (41 N.m).
(2)
Install wire 1138 (6), lockwasher (22) and
nut (21) on starter (23). Tighten nut to 30
lb-ft (41 N.m).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(3)
Apply electrical sealant to terminals (27) and
(28) on starter solenoid (26) and starter (23).
(4)
Position cushion clip (20) over wires 1139
(10) and 1138 (6) and secure cushion clip to
air cleaner bracket (4) with screw (19) and
nut (18).
|