TM 9-2320-364-20-4
7-344
7-99. SLAVE CONNECTOR AND CABLE REPLACEMENT (CONT).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in well-
ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(5)
Apply adhesive to gasket (17).
Ensure receptacle is installed with
positive and negative sides in
same position as noted during
removal. Failure to comply may
result in damage to equipment.
(6)
Install gasket (17), insulator (16) and
receptacle (7) on air cleaner bracket (4)
with three screws (15) and nuts (14).
Tighten screws to 32 lb-in (4 N.m).
(7)
Install eyelet (13) on receptacle (7) with
screw (12) and nut (11). Tighten screw to
32 lb-in (4 N.m).
(8)
Install negative wire 1139 (10) on
receptacle (7) with lockwasher (9) and
screw (8).
(9)
Install positive wire 1138 (6) on
receptacle (7) with lockwasher (5) and
screw (4).
(10)
Apply electrical sealant to positive (6) and
negative (10) connectors.
|