TM 9-2320-364-20-5
19-42
19-13. HEATER BLOWER MOTOR REPLACEMENT (CONT).
(5)
Position blower housing (18) in heater
case (19).
(6)
Connect connector (15) to resistor (16).
(7)
Connect connector (17).
(8)
Install lockwasher (14), ground wire (13),
washer (12), lockwasher (1110) and screw
(10) on center mounting hole.
(9)
Install two washers (9), lockwashers (8) and
screws (7) in outer mounting holes.
(10)
Install heater cover (5) on heater
assembly (6) with six washers (3),
lockwashers (2) clip (4) and screws (1).
c.
Follow-On Maintenance:
Install heater compartment access panel, (Para 17-4).
Connect batteries, (Para 7-87).
Check operation of heater, (TM 9-2320-364-10).
Remove wheel chocks, (TM 9-2320-364-10).
END OF TASK
3
5
4
6
1
2
|