20-5. FAN CONTROL SOLENOID VALVE REPAIR (CONT).
d.
Assembly.
(1)
Apply hydraulic oil to four preformed
packings (5) and install on adapter (1),
elbow (2) and two plugs (3).
(2)
Install adapter (1), elbow (2) and two plugs
(3) on subplate (4).
e.
Installation.
(1)
Install subplate (5) on bracket (14) using
four screws (13) and locknuts (12). Tighten
to 32 lb-in (3 N.m).
(2)
Apply hydraulic oil to two preformed
packings (9) and install on adapter (10) and
elbow (11).
(3)
Install hose (7) on adapter (10) and hose (8)
on elbow (11).
|