TM 9-2320-364-20-5
20-51
Ensure hose 2498 has minimum
of two inches (5 cm) of clearance
from cab upon installation.
Failure to comply may result in
damage to hose.
(19)
With the aid of an assistant, install
preformed packing (21), hose 2498 (20),
two split flanges (19), four lockwashers
(18) and screws (17) on hydraulic reservoir
(22). Tighten screws to 30 lb-ft (41 N.m).
(20)
Install yoke (15) on bracket (16) with
retainer pin (14).
(21)
Install cotter pin (13) in retaining pin (14).
(22)
Install preformed packing (11) and hose
2773 (10) on elbow (12).
Ensure clip is mounted in top
hole of bracket only. Failure to
comply may result in damage to
hose 2773.
(23)
Install clip (8), screw (7) and locknut (6) on
bracket (9) and hose 2773 (10).
|