TM 9-2320-364-20-5
21-196
21-38. CONTAINER HANDLING UNIT (CHU) LIFTING FRAME FLIPPER BRACKET
AND LOCK PLATE REPAIR (CONT).
c.
Installation.
NOTE
There are two flippers and flipper
locks. Both are removed the
same way. Left side is shown.
(1)
Install screw (30) and jam nut (29) on flipper
bracket (17). Do not tighten jam nut.
(2)
Install lock plate (22) with pivot pin (28) and
two cotter pins (27) on flipper bracket (17).
Use care when removing springs.
Springs are under tension and can
act as projectiles when released
and could cause injury to
personnel.
(3)
Install pin handle (26), spring (25), washer
(24) and retaining ring (23) on flipper
bracket (17).
(4)
Install spring (21) on lock plate (22) and
flipper bracket (17).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in
well-ventilated area. If adhesive,
solvent, or sealing compound gets
on skin or clothing, wash
immediately with soap and water.
(5)
Apply light coat of sealing compound to four
bushings (20).
(6)
Install four bushings (20) in boss (19) and
boss (18).
(7)
Position flipper bracket (17) on boss (19)
and boss (18).
23
22
24
25
26
28
29
30
17
27
21
27
20
18
17
19
20
|