TM 9-2320-364-34-2
4-12
4-3. AIR INLET HOUSING REPLACEMENT (CONT).
(3)
Remove ten screws (4) and lockwashers (5)
from air inlet housing (6). Discard
lockwashers.
Use extreme care when
removing air inlet housing from
blower. Failure to comply may
result in serious scratching or
denting of blower.
(4)
Remove air inlet housing (6) and gasket (7)
from blower (8). Discard gasket.
NOTE
Preformed packings may
come off with air inlet
housing or may remain on
blower.
Place clean, dry cloth over
blower to keep blower free
of debris.
(5)
Remove and discard two preformed
packings (9) from air inlet housing (6) or
blower (8).
|