TM 9-2320-364-34-2
5-23
(16)
Install hump hose (4) on water pump (5)
and tighten clamp (3) to 100 lb-in (11 N.m).
(17)
Connect MC71 connector (1) and
MC43 connector (2).
Use care when removing
retaining rings. Retaining rings
are under tension and can act as
projectiles when released
causing injury to personnel.
(18)
Remove retaining ring (26), access
cover (27) and preformed packing (28).
Discard preformed packing.
(19)
Install 5/16-18 by 2 in. screw (29) in
impeller (30).
NOTE
Limits for gear backlash are
0.001 to 0.006 in. (0.025 to
0.152 mm).
(20)
Place plunger of dial indicator against
screw (29). Rotate impeller (30) and read
backlash.
|