TM 9-2320-364-34-2
6-4
6-2. ALTERNATOR ASSEMBLY REPAIR (145 AMP) (CONT).
(8)
Matchmark drive end housing (27), stator (28) and slip ring end housing (20).
(9)
Remove three locknuts (29), screws (30) and washers (31) from slip ring end housing (20) and drive end
housing (27). Discard locknuts.
When removing rotor, completely separate rotor from stator. Stator will still be attached to
slip ring housing. Do not separate stator from slip ring housing, or damage to stator wires
may result.
NOTE
Rotor will remain attached to drive end housing during removal.
(10)
Remove drive end housing (27) and rotor assembly (32) from slip ring end housing (20) and stator (28).
|