TM 9-2320-364-34-2
6-41
(1)
Position field ring (15) in vise.
NOTE
Field coil stud hole in field coil jumper should be aligned with field coil stud hole in field ring.
(2)
Position field coil (84) in field ring (15).
(3)
Position bushing (82) between field coil jumper (83) and field ring (15).
NOTE
Flat side of stud faces brush opening.
(4)
Install field coil stud (9) through field coil jumper (83) and washer (81).
NOTE
Spacer insulation is positioned between field ring and field coil jumper.
(5)
Install spacer insulator (85) in field ring (15).
(6)
Install four pole pieces (80) in field ring (15) with eight screws (79). Tighten screws to 18 to 22 lb-ft
(24 to 30 N.m).
|