TM 9-2320-364-34-2
6-219
(19)
Install wire 1739 (61) on circuit breaker
CB21 (64).
(20)
Install wire 1717 (60) on circuit breaker
CB19 (63).
(21)
Install wires 1755/1723 (59) on circuit
breaker CB18 (62).
(22)
Position wire 1189 (57) on solenoid (58)
with lockwasher (47) and nut (46). Tighten
nut to 10 to 15 lb-in (1 to 2 N.m).
(23)
Position wires 1640/1640 (56) on solenoid
(44) with lockwasher (47) and nut (46).
Tighten nut to 10 to 15 lb-in (1 to 2 N.m).
(24)
Position wires 1072/1702 (54) and wire 1280
(55) on solenoid (44) with lockwasher (42)
and nut (41). Tighten nut to 30 to 35 lb-in (3
to 4 N.m).
NOTE
Leave wire 1435 on ground stud
during ground wire installation.
(25)
Remove nut (49) and washer (51) from
ground stud (53).
(26)
Install ground wire 201 (52) on ground
stud (53) with washer (51), lockwasher (50)
and nut (49).
|