TM 9-2320-364-34-2 6-222      6-25.  ELECTRONIC CONTROL BOX WIRE HARNESS REPLACEMENT (CONT). (37) Install five 12V relays (7) in relay sockets R13 (15), R14 (16), R15 (17), R16 (18) and R17 (19). (38) Install relay socket R11 (12) with lockwasher (14) and screw (13). (39) Install four 12V relays (7) in relay sockets R7 (8), R8 (9), R10 (11) and R11 (12). Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and are harmful to skin and clothing.  To avoid injury or death, keep away from open fire and use in a well-ventilated area.  If adhesive, solvent, or sealing compound gets on skin or clothing, wash immediately with soap and water. (40) Apply sealing compound to mounting surface of MC11 connector (6). (41) Install MC11 connector (6) in ECB (3) with lockwasher (5) and nut (4). (42) Install MC25 connector (2) in ECB (3) with two locknuts (1).