TM 9-2320-364-34-2
6-222
6-25. ELECTRONIC CONTROL BOX WIRE HARNESS REPLACEMENT (CONT).
(37)
Install five 12V relays (7) in relay sockets
R13 (15), R14 (16), R15 (17), R16 (18) and
R17 (19).
(38)
Install relay socket R11 (12) with
lockwasher (14) and screw (13).
(39)
Install four 12V relays (7) in relay sockets
R7 (8), R8 (9), R10 (11) and R11 (12).
Adhesives, solvents, and sealing
compounds can burn easily, can
give off harmful vapors, and are
harmful to skin and clothing. To
avoid injury or death, keep away
from open fire and use in a
well-ventilated area. If adhesive,
solvent, or sealing compound
gets on skin or clothing, wash
immediately with soap and water.
(40)
Apply sealing compound to mounting
surface of MC11 connector (6).
(41)
Install MC11 connector (6) in ECB (3) with
lockwasher (5) and nut (4).
(42)
Install MC25 connector (2) in ECB (3) with
two locknuts (1).
|