TM 9-2320-364-34-2      3-5 (3) Hold push rod (7) and loosen nut (8). NOTE Clearance is 0.016 in. (0.406 mm) for cold or hot setting. (4) Insert feeler gage between valve bridge (9) and valve rocker arm (10) to check clearance. (5) Adjust push rod (7) until slight drag is felt on feeler gage. NOTE Clearance is correct when 0.015 in (0.381 mm) feeler gage passes freely between rocker arm and valve bridge, but the 0.017 in (0.432 mm) feeler gage will not pass through. (6) Remove feeler gage, hold push rod (7) and tighten nut (8).  Recheck clearance. (7) Repeat Steps (1) through (6) for other 15 exhaust valves.