TM 9-2320-364-34-2
6-314
6-31. LHS MAIN WIRE HARNESS REPLACEMENT (CONT).
(4)
Connect MC88 connector (21) to proximity switch (hook arm down) connector (20).
(5)
Install four cushion clips (18) on harness (11).
Adhesives, solvents, and sealing compounds can burn easily, can give off harmful vapors, and
are harmful to skin and clothing. To avoid injury or death, keep away from open fire and use
in a well-ventilated area. If adhesive, solvent, or sealing compound gets on skin or clothing,
wash immediately with soap and water.
NOTE
Do not apply sealing compound to upper screw, until cushion clips have been installed.
(6)
Apply sealing compound to threads of screws (15).
(7)
Install four cushion clips (18) with five washers (17), four lockwashers (16) and four screws (15) to
compression frame tube (14) at inside of left compression frame rail (19).
|